Water Softening Systems


Hard Water contains dissolved minerals in the form of Calcium (Ca), Magnesium (Mg), and Iron (Fe). Removal of these minerals is accomplished by softening the water through an ion exchange process. As the water flows through the mineral tank, the dissolved minerals become attached to the resin, creating soft water. Over a period of time the resin will become exhausted, and the softener will regenerate using a brine solution produced from the salt in the brine tank.

 

Our models based on raw water characteristics and flow rate;

 

AVS FRP TANK SINGLE SOFTENERS

Model

Tank Dimensions inch

Service Flow Rate (m3/h)

Resin (lt)

Salt consumption (kg/rej)

Brine Tank (lt)

AVS-8

8 x 17

1,3

8

1,6

70

AVS-15

7 x 35

1

15

3

70

AVS-20

8 x 35

1,3

20

4

70

AVS-25

9 x 35

1,6

25

5

70

AVS-30

10 x 35

2

30

6

70

AVS-50

10 x 54

2

50

10

100

AVS-60

12 x 52

2,9

60

12

100

AVS-80

13 x 54

3,4

75

15

100

AVS-100

14 x 65

4,0

100

20

150

AVS-150

16 x 65

5,2

150

30

150

AVS-200

18 x 65

6,6

200

40

200

AVS-250

21 x 62

8,9

250

50

200

AVS-300

24 x 72

11,7

300

60

300

AVS-500

30 x 72

18,2

500

100

500

AVS-750

36 x 72

26,3

750

150

750

AVS-900

42 x 72

35,7

900

180

1000

AVS-1200

48 x 72

46,7

1200

240

1500

*Connection diameters are determined based on the project specifications.

** While calculating service flow rate, surface flow rate is accepted as 40m3/m2-h.

*** AVS-8, AVS-15, AVS-20, AVS-25 ve AVS-30 models are also available as cabinet systems.

STANDARD FEATURES

  • Corrosion-resistant FRP tank
  • Time or flow controlled regeneration
  • 3-6 bar operating pressure
  • 10 bar test pressure
  • Max 50 °C operating temperature
  • Cationic resin
  • 220 V / 50 Hz

 

AVDS FRP TANK TWIN ALTERNATING SOFTENERS

Model

Tank Dimensions inch

Service Flow Rate (m3/h)

Resin (lt)

Salt consumption (kg/rej)

Brine Tank (lt)

AVDS-8

8 x 17

1,3

8 x 2

1,6

70

AVDS -15

7 x 35

1

15 x 2

3

70

AVDS -20

8 x 35

1,3

20 x 2

4

70

AVDS -25

9 x 35

1,6

25 x 2

5

70

AVDS -30

10 x 35

2

30 x 2

6

70

AVDS -50

10 x 54

2

50 x 2

10

100

AVDS -60

12 x 52

2,9

60 x 2

12

100

AVDS -80

13 x 54

3,4

75 x 2

15

100

AVDS -100

14 x 65

4,0

100 x 2

20

150

AVDS -150

16 x 65

5,2

150 x 2

30

150

AVDS -200

18 x 65

6,6

200 x 2

40

200

AVDS -250

21 x 62

8,9

250 x 2

50

200

AVDS -300

24 x 72

11,7

300 x 2

60

300

AVDS -500

30 x 72

18,2

500 x 2

100

500

AVDS -750

36 x 72

26,3

750 x 2

150

750

AVDS -900

42 x 72

35,7

900 x 2

180

1000

AVDS -1200

48 x 72

46,7

1200 x 2

240

1500

* While calculating service flow rate, surface flow rate is accepted as 40m3/m2-h.

 

 

STANDARD FEATURES

  • Corrosion-resistant FRP tank
  • Time or flow controlled regeneration
  • 3-6 bar operating pressure
  • 10 bar test pressure
  • Max 50 °C operating temperature
  • High quality cationic resin in compliance with food regulations
  • 220 V / 50 Hz

 

AVIS HIGH FLOW (FACE PIPING) FRP TANK SINGLE SOFTENERS

Model

Tank Dimensions

inch

Connection (Service – Drainage-Brine) (DN)

Flow Rate (m3h)

Minerals

 

 

 

 

Resin (lt)

Quartz (kg)

AVIS-500

30 x 72

50 – 50 – 25

18

500

150

AVIS-750

36 x 72

65 – 50 – 25

26

750

250

AVIS-900

42 x 72

65 – 50 – 25

35

900

300

AVIS-1200

48 x 72

80 – 50 – 40

47

1200

500

AVIS-1600

63 x 86

80 – 80 – 40

80

1800

800

* While calculating service flow rate, surface flow rate is accepted as 40m3/m2-h.

 

 

STANDARD FEATURES

  • Corrosion-resistant FRP tank
  • Time or flow controlled regeneration
  • Pneumatic or electric actuator valves
  • PLC control panel
  • 6 laterals distributor
  • 3-6 bar operating pressure
  • 10 bar test pressure
  • Max 50 °C operating temperature
  • High quality cationic resin in compliance with food regulations /Quartz sand
  • 220 V / 50 Hz

 

AVSS HIGH FLOW (FACE PIPING) CARBON STEEL TANK SINGLE SOFTENERS

Model

Tank Dimensions

inch

Connection (Service – Drainage -Brine) (DN)

Flow Rate (m3h)

Minerals

 

 

 

 

Resin (lt)

Quartz (kg)

AVSS-1250

1250 x 3120

80 – 50 – 40

50

1800

300

AVSS-1600

1600 x 3350

100 – 80 – 50

85

2800

500

AVSS-2000

2000 x 3550

125 – 80 – 50

135

4400

600

AVSS-2400

2400 x 3750

150 – 100 – 80

180

6300

700

* While calculating service flow rate, surface flow rate is accepted as 40m3/m2-h.

AVIDS HIGH FLOW (FACE PIPING) FRP TANK DUPLEX SOFTENERS

Model

Tank Dimensions

inch

Connection (Service – Drainage-Brine) (DN)

Service Flow Rate (m3h)

Minerals

 

Resin (lt)

Quartz (kg)

AVIDS-500

30 x 72

50 – 50 – 25

18

500 x 2

150 x 2

AVIDS-750

36 x 72

65 – 50 – 25

26

750 x 2

250 x 2

AVIDS-900

42 x 72

65 – 50 – 25

35

900 x 2

300 x 2

AVIDS-1200

48 x 72

80 – 50 – 40

47

1200 x 2

500 x 2

AVIDS-1600

63 x 86

80 – 80 – 40

80

1800 x 2

800 x 2

* While calculating service flow rate, surface flow rate is accepted as 40m3/m2-h.

 

STANDARD FEATURES

  • Corrosion-resistant FRP tank
  • Flow controlled regeneration
  • Pneumatic or electric actuator valves
  • PLC control panel
  • 6 laterals distributor
  • 3-6 bar operating pressure
  • 10 bar test pressure
  • Max 50 °C operating temperature
  • High quality cationic resin in compliance with food regulations /Quartz sand
  • 220 V / 50 Hz

 

AVISS HIGH FLOW (FACE PIPING) CARBON STEEL TANK DUPLEX SOFTENERS

Model

Tank Dimensions

inch

Connection (Service – Drainage-Brine) (DN)

Service Flow Rate (m3h)

Minerals

 

 

Resin (lt)

Quartz (kg)

AVISS-1250

1250 x 3120

80 – 50 – 40

50

1800 x 2

300 x 2

AVISS-1600

1600 x 3350

100 – 80 – 50

85

2800 x 2

500 x 2

AVISS-2000

2000 x 3550

125 – 80 – 50

135

4400 x 2

600 x 2

AVISS-2400

2400 x 3750

150 – 100 – 80

180

6300 x 2

700 x 2

* While calculating service flow rate, surface flow rate is accepted as 40m3/m2-h.

 

 

STANDARD FEATURES

  • Epoxy coated carbon steel tank
  • Flow controlled regeneration
  • Pneumatic or electric actuator valves
  • PLC control panel
  • 6 laterals distributor /Filter nozzles
  • 3-6 bar operating pressure
  • 10 bar test pressure
  • Max 50 °C operating temperature
  • High quality cationic resin in compliance with food regulations /Quartz sand
  • 220 V / 50 Hz
  •  

Water softener design is based on raw water characteristics and quantity. Please contact us for further information.