Industrial Reverse Osmosis Systems


Reverse osmosis filters have a pore size around 0.0001 micron. After water passes through a reverse osmosis filter, it is essentially pure water. In addition to removing all organic molecules and viruses, reverse osmosis also removes most minerals that are present in the water. Reverse osmosis removes monovalent ions, which means that it desalinates the water

 

The process of industrial reverse osmosis provides very high quality water for a variety of uses. From drinking water consumption to sea water desalination, reverse osmosis is widely used in homes and industry where high quality, low TDS water is required. Depending on the specific requirements, reverse osmosis (RO) industrial systems are available in many production capacities. For higher volume needs please contact us.

 

Our standard models,

 

AVIRO INDUSTRIAL REVERSE OSMOSIS SYSTEMS

Model

Feed water (m3/day)

Permeate (m3/day)

Membrane dimensions (inch)

Membran quantity

Recovery (%)

AVIRO-1-8040

2

1

8x40

1

50

AVIRO-2-8040

4

2

8x40

2

50

AVIRO-3-8040

5

3

8x40

3

60

AVIRO-4-8040

6,7

4

8x40

4

60

AVIRO-6-8040

10

6

8x40

6

60

AVIRO-8-8040

11,4

8

8x40

8

70

AVIRO-10-8040

14,3

10

8x40

10

70

AVIRO-12-8040

16

12

8x40

12

75

AVIRO-15-8040

21,5

15

8x40

15

75

AVIRO-18-8040

24

18

8x40

18

75

AVIRO-24-8040

32

24

8x40

24

75

AVIRO-30-8040

40

30

8x40

30

75

AVIRO-36-8040

48

36

8x40

36

75

AVIRO-42-8040

56

42

8x40

42

75

AVIRO-48-8040

64

48

8x40

48

75

AVIRO-60-8040

100

60

8x40

60

75

AVIRO-72-8040

96

72

8x40

72

75

AVIRO-96-8040

128

96

8x40

96

75

 
*CIP and rinsing systems are optional.

  

 

DESIGN PARAMETERS

  • Feed water TDS : 0-2000 ppm
  • Feed water pressure: 2-5 bar
  • Feed water temperature: 10 – 30 ° C
  • pH: 6-8
  • Silica (SİO2)  ≤ 25 ppm
  • Turbidity <1 NTU
  • Feed water should not contain oil, grease or biological contamination.
  • Ferrous ≤ 0,05 ppm
  • SDI < 5

 

STANDARD FEATURES
  • FRP membrane housings
  • Low pressure or Standard membrane alternatives.
  • 304SS or epoxy coated carbon steel frames.
  • Cartridge fitler, 5 µ
  • Low pressure tubing U-PVC
  • High pressure tubing U-PVC or 304SS
  • Electrically actuated valves
  • Permeate and reject flow meters
  • Low and high pressure switches
  • Permeate conductivity meter.
  • PLC control panel

 

Industrial Reverse Osmosis system design is based on raw water characteristics and quantity. Please contact us for further information.